Hello, welcome to enter the official website of Qingdao Zhongli Fan Co., LTD.

Treatment scheme for oil leakage at both ends of fan bearing box

Issuing time:2021-04-14 15:58

To solve the leakage problem of fan bearing box, two aspects should be considered, that is, changing the lubrication mode of bearing and improving the structure of shaft seal.


1. Change the lubrication mode of bearings


The only way to change the lubrication mode of bearings is to change thin oil lubrication to grease lubrication;


2, improve the shaft seal structure


The main sealing mode is divided into static seal and dynamic seal two forms according to the relative movement of the seal and the seal. As a rotating machine, the seal of the bearing box of the fan belongs to the dynamic seal.


At present, there are two main types of dynamic sealing: 1) contact sealing 2) non-contact sealing


Share to:
Phone:15066180033  /  0532-87023111
Fax:0532-87023111
E-mail:ktlhfan@126.com
Postcode:266300
Website:http://zhonglifan.com
Adress:17 Xiangjiang Road, Shanghe Economic Demonstration Zone, Jiaozhou, Qingdao